• Title of article

    The Cherenkov radiator system of the high momentum particle identification detector of the ALICE experiment at CERN-LHC

  • Author/Authors

    Pastore، نويسنده , , C. and Sgura، نويسنده , , I. and De Cataldo، نويسنده , , G. and Franco، نويسنده , , A. and Fratino، نويسنده , , U.، نويسنده ,

  • Pages
    3
  • From page
    231
  • To page
    233
  • Abstract
    The aim of this paper is to present the design, the implementation and the operational modes of the Liquid Circulation System (LCS) built to circulate, purify and monitor the liquid perfluorohexane (C6F14) in the ALICE HMPID. The HMPID RICH uses C6F14 as Cherenkov radiator medium circulating in 21 quartz trays. atures a pressure-regulated closed circuit, ensuring the C6F14 highest transparency to ultraviolet light. Intrinsically safe working conditions are obtained, thanks to a novel liquid distribution “cascade” system. er the system is protected against anomalous working conditions by a dedicated Control System, which operates it in both automatic and manual mode, locally and remotely, safeguarding the quartz radiator vessels.
  • Keywords
    HMPID , C6F14 , PLC control , Liquid system
  • Journal title
    Astroparticle Physics
  • Record number

    2016502