Abstract :
The performance of a Micro-Strip Gas Chamber in solution X-ray scattering was studied at the RIKEN structural biology beamline I of the SPring-8 facility. The practical dynamic range was confirmed to be ∼1,000,000 : 1 by measuring S−4 decay from a polystyrene latex solution. Steep troughs of scattering profile from an apoferritin solution were clearly obtained without smearing. An unfolding process of a pH jump of cytochrome c was measured. A time resolution of 500 μs was achieved.