• Title of article

    Radiation test on FD-SOI readout ASIC of pair-monitor for ILC

  • Author/Authors

    Sato، نويسنده , , Yutaro and Arai، نويسنده , , Yasuo and Ikeda، نويسنده , , Hirokazu and Nagamine، نويسنده , , Tadashi and Takubo، نويسنده , , Yosuke and Tauchi، نويسنده , , Toshiaki and Yamamoto، نويسنده , , Hitoshi، نويسنده ,

  • Pages
    5
  • From page
    106
  • To page
    110
  • Abstract
    The pair-monitor is a silicon pixel device that measures the beam profile at the interaction point of the International Linear Collider. It extracts information from the directional distribution of a large number of electron–positron pairs created by collision of bunches, and is required to tolerate radiation dose of about a few Mrad/year. We developed a prototype ASIC with OKI Semiconductor Co., Ltd. 0.2 - μ m fully depleted SOI (FD-SOI) CMOS process and studied its radiation tolerance. In this paper, we describe the design of the readout circuit briefly and present the result of irradiation tests.
  • Keywords
    iLC , Beam profile , Pair-monitor , SOI , Irradiation , Readout ASIC
  • Journal title
    Astroparticle Physics
  • Record number

    2017219