• Title of article

    Multi-layer boron thin-film detectors for neutrons

  • Author/Authors

    Wang، نويسنده , , Zhehui and Morris، نويسنده , , C.L.، نويسنده ,

  • Pages
    3
  • From page
    323
  • To page
    325
  • Abstract
    Intrinsic efficiencies of multi-layer boron-10 thin-film detectors were studied theoretically and experimentally. For multi-layer schemes based on an optimized single-layer film thickness, the practical efficiency is limited to about 42% for thermal neutrons. This is about half the efficiency of a moderated 3He detectors in commercial use for portal monitoring. The efficiency limitation is due to charged particle loss in the boron layers and substrates. The same loss mechanism will prevent all substrate-based boron detectors from ever reaching the intrinsic efficiencies of high-pressure 3He tubes, independent of substrate geometry and material composition. Experimental data also indicate that the multi-layer detector configuration can have an efficiency approaching the theoretical limit. Excellent n / γ discrimination has also been achieved using an ionization chamber.
  • Keywords
    Boron thin-film detector , Efficiency limit , 3He replacement , multi-layer
  • Journal title
    Astroparticle Physics
  • Record number

    2017513