• Title of article

    A study on electron density imaging using the Compton scattered X-ray CT technique

  • Author/Authors

    Yutaka Masuji، نويسنده , , Ryota and Watanabe، نويسنده , , Kenichi and Yamazaki، نويسنده , , Atsushi and Uritani، نويسنده , , Akira، نويسنده ,

  • Pages
    5
  • From page
    620
  • To page
    624
  • Abstract
    We propose a novel electron density imaging technique based on a Compton scattered X-ray CT (CSX-CT) technique. We design fundamental configuration of the CSX-CT system, which consists of a fan-shaped X-ray beam, two-dimensional sensors for scattered X-ray detection, parallel plate collimators for limitation of the direction of scattered X-rays and a line sensor for the transmission of X-ray CT (TX-CT). An image obtained by the TX-CT can be used to correct the attenuation effect of scattered X-rays. Through Monte Carlo simulation modeling studies of the CSX-CT system, we demonstrate that the utilization of the information of scattered X-rays is useful to obtain the electron density image. We additionally confirm that the medical exposure irradiated in the CSX-CT is estimated to be lower than the maximum dose recommended in the guideline of some committees.
  • Keywords
    computed tomography , electron density , Proton and charged particle radiotherapy , Compton scattering
  • Journal title
    Astroparticle Physics
  • Record number

    2017712