Title of article :
The radiation field measurement and analysis outside the shielding of A 10 MeV electron irradiation accelerator
Author/Authors :
Shang، نويسنده , , Jing and Li، نويسنده , , Juexin and Xu، نويسنده , , Bing and Li، نويسنده , , Yuxiong، نويسنده ,
Abstract :
Electron accelerators are employed widely for diverse purposes in the irradiation-processing industry, from sterilizing medical products to treating gemstones. Because accelerators offer high efficiency, high power, and require little preventative maintenance, they are becoming more and more popular than using the 60Co isotope approach. However, the electron accelerator exposes potential radiation hazards. To protect workers and the public from exposure to radiation, the radiation field around the electronic accelerator must be assessed, especially that outside the shielding. Thus, we measured the radiation dose at different positions outside the shielding of a 10-MeV electron accelerator using a new data-acquisition unit named Mini-DDL (Mini-Digital Data Logging). The measurements accurately reflect the acceleratorʹs radiation status. In this paper, we present our findings, results and compare them with our theoretical calculations. We conclude that the measurements taken outside the irradiation hall are consistent with the findings from our calculations, except in the maze outside the door of the accelerator room. We discuss the reason for this discrepancy.
Keywords :
electron irradiation , Electron accelerator , radiation dose
Journal title :
Astroparticle Physics