• Title of article

    Optimization of an X-ray SASE-FEL

  • Author/Authors

    Pellegrini، نويسنده , , C. and Reiche، نويسنده , , S. and Rosenzweig، نويسنده , , J. and Schroeder، نويسنده , , C. and Varfolomeev، نويسنده , , A. I. Tolmachev ، نويسنده , , S. and Nuhn، نويسنده , , H.-D.، نويسنده ,

  • Pages
    6
  • From page
    328
  • To page
    333
  • Abstract
    The most important characteristics of an X-ray SASE-FEL are determined by the electron beam energy, transverse and longitudinal emittance, and by choice of the undulator period, field, and gap. Among them are the gain and saturation length, the amount and spectral characteristics of the spontaneous radiation, the wake fields due to the vacuum pipe. The spontaneous radiation intensity is very large in all X-ray SASE-FELs now being designed, and it contributes to the final electron beam energy spread, thus affecting the gain. It also produces a large background for the beam and radiation diagnostics instrumentation. The wake fields due to the resistivity and roughness of the beam pipe through the undulator, also affects the beam 6-dimensional phase space volume, and thus the gain and the line width. In this paper, we discuss ways to optimize the FEL when considering all these effects. In particular we consider and discuss the use of a hybrid iron-permanent magnet helical undulator to minimize some of these effects, and thus optimize the FEL design.
  • Keywords
    Helical undulator , FEL , Wake fields , X-rays
  • Journal title
    Astroparticle Physics
  • Record number