Title of article
Bakelite RPCs for Digital Hadron Calorimeter
Author/Authors
Zhang، نويسنده , , Qingmin and Wang، نويسنده , , Yifang and Zhang، نويسنده , , Jiawen and Ning، نويسنده , , Zhe and Chen، نويسنده , , Jin and Niu، نويسنده , , Weiping، نويسنده ,
Pages
8
From page
300
To page
307
Abstract
This paper presents the test results of Bakelite RPCs using readout pads with an area of 1 cm×1 cm and 1-bit resolution per pad (binary readout). The results include noise rate, detection efficiency and pad multiplicity as well as comparisons of different surface treatments for Bakelite plates. Pad multiplicity’s dependence on surface resistivity at the readout side is also reported. This study shows Bakelite RPCs can be used as the active elements of digital hadron calorimeter.
Keywords
Bakelite RPC , Digital hadron calorimeter , Surface resistivity
Journal title
Astroparticle Physics
Record number
2018084