Title of article :
Application of a double-sided silicon-strip detector as a differential pumping barrier for NESR experiments at FAIR
Author/Authors :
Streicher، نويسنده , , B. and Egelhof، نويسنده , , P. and Ilieva، نويسنده , , S. and Kalantar-Nayestanaki، نويسنده , , N. and Kollmus، نويسنده , , H. and Krِll، نويسنده , , Th. and Mutterer، نويسنده , , M. and von Schmid، نويسنده , , M. and Trنger، نويسنده , , M.، نويسنده ,
Pages :
4
From page :
604
To page :
607
Abstract :
The presented work focuses on the development of a differential pumping system using double-sided silicon-strip detectors to separate the ultra-high vacuum of a storage ring from subsequent detectors and outgassing components placed in an auxiliary vacuum. Such a technical concept will give the opportunity to use telescope-like detector systems in an ultra-high vacuum environment, such as a storage ring, without enclosing the entire system in a pocket. Therefore, it will enable the detection of recoil particles with the smallest possible energy due to the use of the innermost strip detector as an active window. Our results prove that such an assembly is feasible without having an effect, within experimental errors, on the performance of the strip detector. Vacuum separation better than six orders of magnitude was achieved with the ultra-high vacuum side reaching down to the 10 − 10 mbar pressure region.
Keywords :
Double-sided silicon-strip detector , Differential vacuum , storage ring
Journal title :
Astroparticle Physics
Record number :
2018172
Link To Document :
بازگشت