• Title of article

    Performance and applications of a high rate imaging pixel detector

  • Author/Authors

    Pavel، نويسنده , , N.A. and Besch، نويسنده , , H.J. and Menk، نويسنده , , R. Rohani Sarvestani، نويسنده , , A. and Sauer، نويسنده , , N. and Stiehler، نويسنده , , R. and Walenta، نويسنده , , A.H.، نويسنده ,

  • Pages
    4
  • From page
    313
  • To page
    316
  • Abstract
    In the past years a large variety of gas filled micro pattern detectors have been developed for applications in high energy physics as well as for X-ray imaging in synchrotron light experiments. Here, we present the most recent developments on the MicroCAT detector with resistive position encodeing readout, which has been demonstrated to meet even the strong requirements in high resolution protein crystallography and time resolved small angle scattering at synchrotron light sources of the third generation. Recent test measurements with the prototype under the working conditions of a synchrotron light source as well as high time resolved measurements in the laboratory are presented.
  • Keywords
    Hight rate X-ray imaging , Time resolved measurements , Micro pattern detectors , Protein Crystallography , Small angle scattering at synchrotron light sources
  • Journal title
    Astroparticle Physics
  • Record number

    2018320