• Title of article

    Development of large area and of position-sensitive timing RPCs

  • Author/Authors

    Blanco، نويسنده , , A and Ferreira Marques، نويسنده , , R and Finck، نويسنده , , Ch and Fonte، نويسنده , , P and Gobbi، نويسنده , , A and Mendiratta، نويسنده , , S.K and Monteiro، نويسنده , , J and Policarpo، نويسنده , , A and Rozas، نويسنده , , M، نويسنده ,

  • Pages
    6
  • From page
    170
  • To page
    175
  • Abstract
    Resistive Plate Chambers (RPC) made with glass and metal electrodes forming accurately spaced gas gaps of a few hundred micrometers have reached timing accuracies below 50 ps σ with efficiencies above 99% for MIPs. This type of detector, operating at atmospheric pressure with non-flammable gases, seems well suited for large TOF systems, providing performances comparable to the scintillator-based TOF technology with significantly lower price per channel and being compatible with magnetic fields. s work, we report recent developments of the timing RPC technology, including a large area counter (0.16 m2) and smaller, position-sensitive, single-gap counters. The latter devices are aimed to be applied in small and accurate TOF systems using a multilayer structure. rge counter has shown a timing resolution between 50 and 75 ps σ over the whole active area, with 96% efficiency and very small timing tails, along with a longitudinal position-resolution of 1.2 cm σ. The single-gap counters had a timing resolution of 55 ps σ and a bi-dimensional position-resolution better than 3 mm FWHM. It was calculated that a 4-layer configuration of such counters would yield a time resolution of 33 ps σ essentially free from timing tails.
  • Keywords
    RPC , TOF , Gaseous detectors , Time resolution
  • Journal title
    Astroparticle Physics
  • Record number

    2018445