• Title of article

    A new optimised quadrupole pick-up design using magnetic coupling

  • Author/Authors

    Jansson، نويسنده , , A. and Williams، نويسنده , , D.J.، نويسنده ,

  • Pages
    10
  • From page
    233
  • To page
    242
  • Abstract
    The idea of quadrupole pick-ups, sensitive to beam size, originated several decades back. Such pick-ups measure the quantity σx2−σy2, where σx and σy are the horizontal and vertical r.m.s. beam sizes. Thus, a quadrupole pick-up is a candidate for non-invasive study of processes such as coherent beam width oscillations due to injection mismatch. Up to now, quadrupole pick-ups have been produced essentially by enhancing the electronics of normal position pick-ups to produce the so-called quadrupole signal, with little or no effort being put into the design of the pick-up itself. In developing a quadrupole pick-up for the CERN PS, however, it has been found necessary to optimise the pick-up design. The result is a somewhat unconventional pick-up, where magnetic coupling is employed to suppress the otherwise very strong, and undesired, common mode-signal. In this paper, the basic design idea and the final optimised design are presented, together with simulations, test bench measurements and real beam data.
  • Keywords
    Magnetic coupling , Quadrupole pick-up , Beam-size measurement
  • Journal title
    Astroparticle Physics
  • Record number

    2018525