Title of article :
The charge state distribution of a carbon beam measured at the lund pelletron accelerator with the newly installed terminal pumping system in use
Author/Authors :
Kiisk، نويسنده , , Madis and Erlandsson، نويسنده , , Bengt and Faarinen، نويسنده , , Mikko and Hellborg، نويسنده , , Ragnar and Hهkansson، نويسنده , , Kjell and Persson، نويسنده , , Per and Skog، نويسنده , , Gِran and Stenstrِm، نويسنده , , Kristina، نويسنده ,
Pages :
8
From page :
1
To page :
8
Abstract :
Charge state distributions for 12C and 13C ions have been measured at the Lund Pelletron tandem accelerator for the N2 gas stripper with a newly installed terminal pumping system in use. A comparison of the results obtained for the ion energies between 1.5 and 2.8 MeV with the foil stripper and the gas stripper without terminal pumping demonstrates the great improvement of the stripping process achieved with the new terminal pumping.
Journal title :
Astroparticle Physics
Record number :
2018829
Link To Document :
بازگشت