Title of article
Performance of a proton irradiation chamber
Author/Authors
Agosteo، نويسنده , , S. and Borsato، نويسنده , , E. and Dal Corso، نويسنده , , F. and Fazzi، نويسنده , , A. and Gonella، نويسنده , , F. and Introini، نويسنده , , M.V. and Lippi، نويسنده , , I. and Lorenzoli، نويسنده , , M. and Modenese، نويسنده , , L. and Montecassiano، نويسنده , , F. and Pegoraro، نويسنده , , M. and Pola، نويسنده , , A. and Varoli، نويسنده , , V. and Zotto، نويسنده , , P.، نويسنده ,
Pages
10
From page
193
To page
202
Abstract
A Proton Irradiation Chamber aiming to perform radiation tests of electronic components was developed. The precision on the measurement of the ion currents was pushed beyond the resolution of the picoammeter by means of a series of collimators on the beam showing a linear correlation among the currents measured on them and the smaller, not measurable, current on the target. As an example of the obtained results the tests done on a Si microdosimeter and a power p-MOS are reported.
Keywords
Radiation tests , Electronics radiation resistance , Total dose resistance
Journal title
Astroparticle Physics
Record number
2018830