• Title of article

    Assessment of a Compton-event suppression γ-spectrometer for the detection of fission products at trace levels

  • Author/Authors

    Peerani، نويسنده , , Paolo and Carbol، نويسنده , , Paul and Hrnecek، نويسنده , , Erich and Betti، نويسنده , , Maria، نويسنده ,

  • Pages
    9
  • From page
    42
  • To page
    50
  • Abstract
    The improvement in detection limits for low and high activity samples measured with the Compton-suppression γ-spectrometer installed at the Institute for Transuranium Elements (ITU) for environmental monitoring of radioactivity, as well as nuclear safeguards, is discussed. The advantage of using two parallel acquisition lines for simultaneous measurement with and without Compton-event suppression is outlined with respect to cascade and non-cascade γ-emitters. The background reduction by Compton-event suppression made it possible to detect small peaks, which otherwise would not have been found in a conventional spectrum. In Compton-event suppression mode, the detection limit for 137Cs was improved by a factor of about 3, for 241Am we found a factor of 1.2 both in high and low active samples. The measurements of environmental reference samples showed good agreement with certified values in both acquisition modes. The application of this instrument for the determination of fission products in smear samples is described. In particular, for nuclides like 54Mn, 125Sb and 144Ce, an improvement in the detection limits by a factor of 1.6–2.4 was obtained.
  • Keywords
    ?-spectrometry , Compton-event suppression , Environmental reference samples , Smear samples
  • Journal title
    Astroparticle Physics
  • Record number

    2018964