• Title of article

    Characterisation of the low-energy photon attenuation in gamma-ray spectroscopy of bituminized radioactive waste drums using a peak-to-Compton ratio

  • Author/Authors

    Perot، نويسنده , , B. and Pin، نويسنده , , P.، نويسنده ,

  • Pages
    6
  • From page
    76
  • To page
    81
  • Abstract
    In gamma-ray spectroscopy of radioactive waste, the uncertainty on the activity can be very high for low energy photons – particularly below 100 keV – if the chemical composition of the matrix is not known with a good precision. Particularly, high atomic number (high-Z) elements increase photoelectric absorption. We present here the development of a new method characterizing photon attenuation in a homogeneous waste matrix, using a peak-to-Compton ratio extracted from the gamma spectrum.
  • Keywords
    radioactive waste , Gamma-ray spectroscopy , Matrix self-absorption , Peak-to-Compton ratio , High-purity germanium detector
  • Journal title
    Astroparticle Physics
  • Record number

    2019095