• Title of article

    Transverse electron beam imaging system using visible synchrotron radiation at MAX III

  • Author/Authors

    Hansson، نويسنده , , A. and Wallén، نويسنده , , E. and Andersson، نويسنده , , إ.، نويسنده ,

  • Pages
    9
  • From page
    94
  • To page
    102
  • Abstract
    The diagnostic beam line at the MAX III synchrotron light source utilizes the synchrotron radiation (SR) in the visible to ultraviolet range to form images of the transverse electron beam profile. The emission and subsequent propagation and focusing of the SR is modeled, taking into account effects such as diffraction and the longitudinally distributed SR generation. A detailed description of the setup of the beam line and method used to determine the transverse beam profile is given in the paper. In order to investigate the imaging method, a series of measurements were performed where the beam line configuration was varied to utilize different wavelengths and polarizations of the SR and different horizontal opening angles of the measurement system. A suggestion is made how to measure future small horizontal beam sizes.
  • Keywords
    Electron beam profile , Synchrotron radiation
  • Journal title
    Astroparticle Physics
  • Record number