Title of article :
STAR barrel electromagnetic calorimeter absolute calibration using “minimum ionizing particles” from collisions at RHIC
Author/Authors :
Cormier، نويسنده , , T.M and Pavlinov، نويسنده , , A.I and Rykov، نويسنده , , M.V and Rykov، نويسنده , , V.L and Shestermanov، نويسنده , , K.E، نويسنده ,
Pages :
13
From page :
734
To page :
746
Abstract :
The procedure for the STAR Barrel Electromagnetic Calorimeter (BEMC) absolute calibrations, using penetrating charged particle hits (MIP-hits) from physics events at RHIC, is presented. Its systematic and statistical errors are evaluated. It is shown that, using this technique, the equalization and transfer of the absolute scale from the test beam can be done to a percent level accuracy in a reasonable amount of time for the entire STAR BEMC. MIP-hits would also be an effective tool for continuously monitoring the variations of the BEMC towerʹs gains, virtually without interference to STARʹs main physics program. The method does not rely on simulations for anything other than geometric and some other small corrections, and also for estimations of the systematic errors. It directly transfers measured test beam responses to operations at RHIC.
Keywords :
Monitoring , RHIC , STAR , Electromagnetic calorimeter , Calibration , charged particles
Journal title :
Astroparticle Physics
Record number :
2019277
Link To Document :
بازگشت