Author/Authors :
Park، نويسنده , , K.S and Park، نويسنده , , J.S. and Kim، نويسنده , , B.C. and Shin، نويسنده , , J.W. and Ahn، نويسنده , , J.K. and Choi، نويسنده , , S. and Choi، نويسنده , , Y. and Jang، نويسنده , , H.I. and Jang، نويسنده , , J.S. and Jeon، نويسنده , , E.J. and Joo، نويسنده , , K.K. and Kim، نويسنده , , B.R and Kim، نويسنده , , H.S. and Kim، نويسنده , , Jy-Yeon Kim، نويسنده , , S.B. and Kim، نويسنده , , W. and Kim، نويسنده , , Y.D. and Lee، نويسنده , , J. and Lim، نويسنده ,
Abstract :
The aim of the RENO (Reactor Experiment for Neutrino Oscillation) is to measure the smallest neutrino mixing angle, θ 13 . The RENO detector consists of four concentric cylindrical layers: the target, γ - catcher , buffer and veto. Acrylic is used for the target and γ - catcher vessels, both of which contain liquid scintillator. Acrylic was chosen because it has good transmittance in the wavelength range of 400 – 430 nm and also does not react with liquid-scintillating solvents. In order to reduce systematic uncertainties, the target volume should be identical to a level of less than 0.1% between the near and far detectors. Furthermore, the acrylic vessel should not have any leaks. In this paper, we investigate the optical properties, design and construction of the acrylic vessels used in the RENO detector.
Keywords :
Neutrino oscillation , Reno , Leakage test , acrylic