Author/Authors :
Fukami، نويسنده , , Kenji and Hasegawa، نويسنده , , Makoto and Kobayashi، نويسنده , , Kazuo T. Nakamura، نويسنده , , Takeshi and Mitsuda، نويسنده , , Chikaori and Nakanishi، نويسنده , , Tatsurou and Ohshima، نويسنده , , Takashi and Oishi، نويسنده , , Masaya and Shoji، نويسنده , , Masazumi and Soutome، نويسنده , , Kouichi and Suzuki، نويسنده , , Motohiro and Zhang، نويسنده , , Chao، نويسنده ,
Abstract :
The top-up operation mode is becoming the standard operation mode in most facilities of third-generation light sources. In the top-up operation mode, it is important to keep the stored beam stable during beam injection in order for synchrotron radiation users to continue their experiments without disturbance. The injection bump magnets, however, have some alignment error in their rotation around the beam axis (tilt error), and this causes oscillation of the stored beam in the vertical direction. To suppress this oscillation, we developed a beam-based method of aligning the bump magnets using a remote-controlled tilt adjustment system. Applying the method, we could reduce the amplitude of the vertical oscillation to 0.4 μ m , which is approximately 1/40 of the r.m.s. beam size in the vertical direction.
Keywords :
Injection bump magnet , Beam-based alignment , tilt , Vertical oscillation , Top-up