Title of article :
Experimental and simulated efficiency of a HPGe detector with point-like and extended sources
Author/Authors :
Karamanis، نويسنده , , D and Lacoste، نويسنده , , V and Andriamonje، نويسنده , , S and Barreau، نويسنده , , G and Petit، نويسنده , , M، نويسنده ,
Pages :
11
From page :
477
To page :
487
Abstract :
The absolute efficiency of a high purity germanium (HPGe) detector was determined with a point-like calibrated 152Eu source at two distances from the detector and three pure metallic thorium foils of different thicknesses. The experimental values are compared with the ones determined with the simulation codes MCNP4B and GEANT 3.21. A procedure for HPGe absolute efficiency calibration is proposed for γ-ray energies higher than 200 keV.
Keywords :
HPGe detector , efficiency , thorium , Monte Carlo