Title of article :
Sub-micron resolution rf cavity beam position monitor system at the SACLA XFEL facility
Author/Authors :
Maesaka، نويسنده , , H. and Ego، نويسنده , , H. and Inoue، نويسنده , , S. and Matsubara، نويسنده , , S. and Ohshima، نويسنده , , T. and Shintake، نويسنده , , T. and Otake، نويسنده , , Y.، نويسنده ,
Pages :
9
From page :
66
To page :
74
Abstract :
We have developed and constructed a C-band (4.760 GHz) rf cavity beam position monitor (RF-BPM) system for the XFEL facility at SPring-8, SACLA. The demanded position resolution of the RF-BPM is less than 1 μ m , because an electron beam and x-rays must be overlapped within 4 μ m precision in the undulator section for sufficient FEL interaction between the electrons and x-rays. In total, 57 RF-BPMs, including IQ demodulators and high-speed waveform digitizers for signal processing, were produced and installed into SACLA. We evaluated the position resolutions of 20 RF-BPMs in the undulator section by using a 7 GeV electron beam having a 0.1 nC bunch charge. The position resolution was measured to be less than 0.6 μ m , which was sufficient for the XFEL lasing in the wavelength region of 0.1 nm, or shorter.
Keywords :
BPM , XFEL , Linac , linear accelerator , Rf cavity beam position monitor
Journal title :
Astroparticle Physics
Record number :
2020221
Link To Document :
بازگشت