Title of article
Fast beam cut-off method in RF-knockout extraction for spot-scanning
Author/Authors
Furukawa، نويسنده , , Takuji and Noda، نويسنده , , Koji، نويسنده ,
Pages
9
From page
59
To page
67
Abstract
An irradiation method with magnetic scanning has been developed in order to provide accurate irradiation even for an irregular target shape. The scanning method has strongly required a lower ripple of the beam spill and a faster response to beam-on/off in slow extraction from a synchrotron ring. At HIMAC, RF-knockout extraction has utilized a bunched beam to reduce the beam-spill ripple. Therefore, particles near the resonance can be spilled out from the separatrices by synchrotron oscillation as well as by a transverse RF field. From this point of view, a fast beam cut-off method has been proposed and verified by both simulations and experiments. The maximum delay from the beam cut-off signal to beam-off has been improved to around 60 μs from 700 μs by a usual method. Unwanted dose has been considerably reduced by around a factor of 10 compared with that by the usual method.
Keywords
RF-knockout slow extraction , Heavy-ion therapy , Synchrotron , Spot-scanning , Dose management
Journal title
Astroparticle Physics
Record number
2020281
Link To Document