Title of article :
Construction and performance of the PHENIX pad chambers
Author/Authors :
K. Adcox، نويسنده , , K. and Ajitanand، نويسنده , , J. and Alexander، نويسنده , , J. and Barrette، نويسنده , , J. and Belkin، نويسنده , , J.Simon R. and Borland، نويسنده , , D. and Bryan، نويسنده , , W.L. and du Rietz، نويسنده , , R. and El Chenawi، نويسنده , , K. and Cherlin، نويسنده , , A. and Fellenstein، نويسنده , , J. and Filimonov، نويسنده , , K. and Fraenkel، نويسنده , , Z. and Gan، نويسنده , , D. and Garpman، نويسنده , , S. and Gil، نويسنده , , Y. and Greene، نويسنده , , S.V. and Gustafsson، نويسنده , , H.-إ. and Holzmann، نويسنده , , W. and Issah، نويسنده , , M. and Jagadish، نويسنده , , U. and Lacey، نويسنده , , R. and Lauret، نويسنده , , J. and Liccardi، نويسنده , , Dale W. and Mark، نويسنده , , S.K. and Milan، نويسنده , , J. and Miller، نويسنده , , T.E. and Milov، نويسنده , , A. and Mitchell، نويسنده , , J.T. and Nilsson، نويسنده , , P. and Nikkinen، نويسنده , , L. and Nystrand، نويسنده , , J. and OʹBrien، نويسنده , , E. and Oskarsson، نويسنده , , A. and ضsterman، نويسنده , , L. and Otterlund، نويسنده , , I. and Qi، نويسنده , , Y. and Pasmantirer، نويسنده , , B. and Pinkenburg، نويسنده , , C. and Ravinovich، نويسنده , , I. and Rosati، نويسنده , , M. and Rose، نويسنده , , A. and Silvermyr، نويسنده , , D. and Sivertz، نويسنده , , M. and Smith، نويسنده , , M.C. and Starinsky، نويسنده , , N. and Stenlund، نويسنده , , Frederic E. and Teodorescu، نويسنده , , O. and Tserruya، نويسنده , , I. and Tydesjِ، نويسنده , , H. Q. Xie، نويسنده , , W. and Young، نويسنده , , G.R. and Yurevich، نويسنده , , V.، نويسنده ,
Pages :
31
From page :
263
To page :
293
Abstract :
We present the Pad Chamber detector system in the PHENIX experiment at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The three station system provides space points along each track in the spectrometer arms at mid-rapidity and covers a total area of 88 m2. Its main functions are to provide the track coordinate along the beam and to ensure reliable pattern recognition at very high particle multiplicity. A new concept for two dimensional wire chamber readout via its finely segmented cathode was developed. The full readout system, comprising 172 800 electronic channels, is described together with the challenging design of the chambers. The electronics, mounted on the outer chamber face, together with the chamber itself amounts to 1.2% of a radiation length. Results from cosmic ray tests, showing an average efficiency better than 99.5% for all chambers are presented. The experiences from the full scale operation in the first run are reported.
Keywords :
PHENIX , RHIC , Wire chamber , Tracking , Readout electronics , Cathode pixels
Journal title :
Astroparticle Physics
Record number :
2020473
Link To Document :
بازگشت