    Effects of the induction-gap parameters on the signal in a double-GEM detector

  • Author/Authors

    Guedes، نويسنده , , G.P. and Breskin، نويسنده , , A. and Chechik، نويسنده , , R. and Mِrmann، نويسنده , , D.، نويسنده ,

  • Pages
    9
  • From page
    305
  • To page
    313
  • Abstract
    A study of a dual-GEM detector coupled to a strip readout anode is described. The effects of the induction electric field and GEM-to-anode gap are presented, for an operation in atmospheric pressure Ar/CO2 (70/30) and Ar/CH4 (95/5). Visible gain and anode signal pulse-shapes, measured with 5.9 keV X-rays are presented for 1–6 mm wide induction gaps and for induction fields ranging up to 6 kV cm−1. The spatial distribution of the anode charge is provided for induction gaps of 2–12 mm. The results are useful for matching the detector parameters to the position recording circuit requirements.
  • Keywords
    Gaseous detector , Avalanche-induced signals , x-ray detection , GEM , Gas electron multiplier
  • Journal title
    Astroparticle Physics