Title of article :
The RHIC magnet system
Author/Authors :
B. and Anerella، نويسنده , , M and Cottingham، نويسنده , , J and Cozzolino، نويسنده , , J and Dahl، نويسنده , , P and Elisman، نويسنده , , Y and Escallier، نويسنده , , J and Foelsche، نويسنده , , V. and Ganetis، نويسنده , , G and Garber، نويسنده , , M and Ghosh، نويسنده , , Kristin B. and Goodzeit، نويسنده , , C and Greene، نويسنده , , A and Gupta، نويسنده , , R and Harrison، نويسنده , , M and Herrera، نويسنده , , J and Jain، نويسنده , , A and Kahn، نويسنده , , S and Kelly، نويسنده , , E and Killian، نويسنده , , E and Lindner، نويسنده , , M and Louie، نويسنده , , W and Marone، نويسنده , , A and Morgan، نويسنده , , G and Morgillo، نويسنده , , A and Mulhall، نويسنده , , S and Muratore، نويسنده , , J and Plate، نويسنده , , S and Prodell، نويسنده , , A and Rehak، نويسنده , , M and Rohrer، نويسنده , , E and Sampson، نويسنده , , W and Schmalzle، نويسنده , , J and Schneider، نويسنده , , W and Shutt، نويسنده , , R and Sintchak، نويسنده , , G and Skaritka، نويسنده , , J and Thomas، نويسنده , , R and Thompson، نويسنده , , P and Wanderer، نويسنده , , P and Willen، نويسنده , , E، نويسنده ,
Pages :
36
From page :
280
To page :
315
Abstract :
The magnet system of the collider consists of superconducting dipole, quadrupole and correction magnets for guiding and focusing the beams through the regular arcs of the machine lattice as well as into collision at the six interaction points. It is designed to allow operation in the energy range 30–100 GeV/u. Operation with either equal or unequal ion species in the colliding beams is possible, imposing a ratio of up to 2.5:1 in the magnetic fields of the two rings. There are 1740 superconducting magnets in the machine. They were designed to meet stringent requirements on field quality, reproducibility, and long-term reliability while being inexpensive to produce. Wherever feasible, production of magnets and components was carried out in industry, always with build-to-print designs. After several years of operation, no magnet has failed and the magnet system has proven reliable and functional.
Keywords :
Helical magnets , Superconducting magnets , RHIC magnets , Magnet field quality , Accelerator magnets
Journal title :
Astroparticle Physics
Record number :
2020665
Link To Document :
بازگشت