• Title of article

    Nondestructive waste-drum assay for transuranic content by gamma-ray active and passive computed tomography

  • Author/Authors

    Camp، نويسنده , , D.C and Martz، نويسنده , , H.E and Roberson، نويسنده , , G.P and Decman، نويسنده , , D.J and Bernardi، نويسنده , , R.T، نويسنده ,

  • Pages
    15
  • From page
    69
  • To page
    83
  • Abstract
    A gamma-ray-based, active (A) and passive (P) computed tomography (CT) technology has been developed that locates, identifies and quantifies gamma-ray emitting isotopes, transuranic (TRU) and others, in nuclear waste drums. ACT uses a collimated external source and a HPGe detector to measure selected mono-energetic gamma-rays that are attenuated by waste-drum contents; a separate PCT measurement uses the HPGe detector to record the spectra of gamma-rays emitted from within a drum. The ACT attenuation images and the PCT emission spectra are coupled to quantitatively assay drum contents for ∼0.1–200 g of TRU isotopes. Calibration requires a single measurement of a known radioactive standard; construction of waste-drum surrogates is not required. Fixed and mobile systems demonstrated compliance with a DOE quality assurance program via several independent blind tests.
  • Keywords
    Nondestructive assay , Gamma-ray spectroscopy , Transuranic isotopes , Active (transmission) and passive (emission) computed tomography
  • Journal title
    Astroparticle Physics
  • Record number

    2020783