Title of article
The pressure profile in the Lund Pelletron accelerator with the newly installed terminal pumping in use
Author/Authors
Persson، نويسنده , , P and Hellborg، نويسنده , , R and Kiisk، نويسنده , , M and Skog، نويسنده , , G and Stenstrِm، نويسنده , , K، نويسنده ,
Pages
7
From page
55
To page
61
Abstract
Terminal pumping has recently been installed in the Lund tandem Pelletron electrostatic accelerator. The equipment allows a higher gas density in the stripper and an improved vacuum in the accelerator tubes compared to the former system. This improvement has led to an increased beam transmission and to superior measurements for our accelerator mass spectrometry programme. The pressure profile of the stripper system as well as of the accelerator tubes has been calculated using kinetic gas theory. The result will be used to identify possible technical improvements in the future.
Keywords
Pressure profile , Terminal pumping , Tandem accelerator
Journal title
Astroparticle Physics
Record number
2021010
Link To Document