Title of article :
Dosimetry with a recombination chamber in outdoor conditions and at low dose rates
Author/Authors :
Zielczynski، نويسنده , , Mieczyslaw and Golnik، نويسنده , , Natalia and Rusinowski، نويسنده , , Zdzis?aw and Tulik، نويسنده , , Piotr، نويسنده ,
Pages :
10
From page :
421
To page :
430
Abstract :
A system with a recombination chamber for outdoor dosimetry in mixed radiation fields is proposed. The chamber works as a passive detector, with polarising electrodes supplied from capacitors permanently connected to the electrodes. Ions, collected on the measuring electrode, charge a measuring capacitor, also permanently connected to the electrode. A special procedure, including recharging of the supplying capacitors, was introduced in order to compensate the side charge caused by changes of ambient temperature and leakage of the electrical charge from the supplying capacitors. Experimental tests indicated that the chamber of REM-2 type or a specially designed KR-20 chamber could also be used at low dose rates. It was possible to measure the ambient dose of a fraction of μGy with accuracy of about 10%, and the H*(10) of about 1 μSv, with accuracy better than 25%, in any field of penetrating radiation, provided the time of charge collection is less than 24 h.
Keywords :
Recombination chambers , Outdoor dosimetry
Journal title :
Astroparticle Physics
Record number :
2021156
Link To Document :
بازگشت