• Title of article

    Modeling skin effect in large magnetized iron detectors

  • Author/Authors

    Incurvati، نويسنده , , M. Livia Terranova، نويسنده , , F.، نويسنده ,

  • Pages
    5
  • From page
    441
  • To page
    445
  • Abstract
    The experimental problem of the calibration of magnetic field in large iron detectors is discussed. Emphasis is laid on techniques based on ballistic measurements as the ones employed by MINOS or OPERA. In particular, we provide analytical formulas to model the behavior of the apparatus in the transient regime, keeping into account eddy current effects and the finite penetration velocity of the driving fields. These formulas ease substantially the design of the calibration apparatus. Results are compared with experimental data coming from a prototype of the OPERA spectrometer.
  • Keywords
    Magnetic spectrometers , Eddy currents , Neutrino detectors
  • Journal title
    Astroparticle Physics
  • Record number

    2021159