Title of article
Modeling skin effect in large magnetized iron detectors
Author/Authors
Incurvati، نويسنده , , M. Livia Terranova، نويسنده , , F.، نويسنده ,
Pages
5
From page
441
To page
445
Abstract
The experimental problem of the calibration of magnetic field in large iron detectors is discussed. Emphasis is laid on techniques based on ballistic measurements as the ones employed by MINOS or OPERA. In particular, we provide analytical formulas to model the behavior of the apparatus in the transient regime, keeping into account eddy current effects and the finite penetration velocity of the driving fields. These formulas ease substantially the design of the calibration apparatus. Results are compared with experimental data coming from a prototype of the OPERA spectrometer.
Keywords
Magnetic spectrometers , Eddy currents , Neutrino detectors
Journal title
Astroparticle Physics
Record number
2021159
Link To Document