Title of article :
Undulator system for the VUV FEL at the TESLA test facility phase-2
Author/Authors :
Pflüger، نويسنده , , J and Hahn، نويسنده , , U and Faatz، نويسنده , , B and Tischer، نويسنده , , M، نويسنده ,
Abstract :
The Phase-1 of the VUV Free Electron Laser at the TESLA Test Facility finishes in fall 2002. Phase-2, an extension of Phase-1 towards shorter wavelengths is under construction and will be ready for operation in 2003. A radiation wavelength as low as 6 nm will be obtained by raising the electron energy to 1 GeV. There will be only minor changes to the undulator system. Compared to Phase-1, six instead of three undulator segments will be installed. The integrated focusing system will be replaced by an electromagnetic doublet structure. We report about the changes of the undulator, the undulator vacuum system, the separated quadrupoles including a stretched wire alignment systems and the modifications to the beam diagnostic system consisting of pick up monitors and wire scanners.
Keywords :
Wire scanner , Quadrupole alignment , TESLA TTF , FEL , Undulator
Journal title :