Title of article :
Scintillation fiber array detector for measurement of neutron beam profile
Author/Authors :
Kim، نويسنده , , Chong and Hong، نويسنده , , Byungsik and Jo، نويسنده , , Mihee and Lee، نويسنده , , Kyong Sei and Sim، نويسنده , , Kwang-Souk، نويسنده ,
Pages :
5
From page :
276
To page :
280
Abstract :
We built and tested a detector to measure the profile of fast-neutron beams delivered by the MC50 cyclotron at the Korea Institute of Radiological and Medical Science (KIRAMS). The core component of the detector is a 2 × 46 array of scintillation fibers. The light output of the scintillation fibers is transformed into a current signal by a 46-channel silicon photodiode and digitized by a current-mode signal processor. This scanning device was designed to cover a neutron beam area of 30 × 32 cm 2 . The detector was tested in a neutron beam delivered by the MC50 cyclotron at KIRAMS. We demonstrate that the detector can successfully measure the neutron beam profile at various beam currents from 10 to 20 μ A . The proposed neutron beam profile detector will be useful, for example, in radiotherapy applications with neutron intensities above 10 7 Hz / cm 2 .
Keywords :
Scintillation fiber , Neutron beam , Current-mode electronics , Proton accelerator , Line scanning
Journal title :
Astroparticle Physics
Record number :
2022640
Link To Document :
بازگشت