• Title of article

    The Columbia University sub-micron charged particle beam

  • Author/Authors

    Randers-Pehrson، نويسنده , , Gerhard and Johnson، نويسنده , , Gary W. and Marino، نويسنده , , Stephen A. and Xu، نويسنده , , Yanping and Dymnikov، نويسنده , , Alexander D. and Brenner، نويسنده , , David J.، نويسنده ,

  • Pages
    6
  • From page
    294
  • To page
    299
  • Abstract
    A lens system consisting of two electrostatic quadrupole triplets has been designed and constructed at the Radiological Research Accelerator Facility (RARAF) of Columbia University. The lens system has been used to focus 6 MeV 4He ions to a beam spot in air with a diameter of 0.8 μm. The quadrupole electrodes can withstand voltages high enough to focus 4He ions up to 10 MeV and protons up to 5 MeV. The quadrupole triplet design is novel in that alignment is made through precise construction and the relative strengths of the quadrupoles are accomplished by the lengths of the elements, so that the magnitudes of the voltages required for focusing are nearly identical. The insulating sections between electrodes have had ion implantation to improve the voltage stability of the lens. The lens design employs Russian symmetry for the quadrupole elements.
  • Keywords
    Sub-micron , Charged particle beam , quadrupole , microbeam , Electrostatic
  • Journal title
    Astroparticle Physics
  • Record number

    2022643