Title of article :
LED pulser system for Fermilabʹs Dط Muon Scintillation counters
Author/Authors :
Hanlet، نويسنده , , P. and Doulas، نويسنده , , Alexander S. and Kirsch، نويسنده , , N. and Marcus، نويسنده , , M. and Wood، نويسنده , , D.R. and Haggerty، نويسنده , , H. and Hansen، نويسنده , , S. and Ito، نويسنده , , A.S. and Jones، نويسنده , , R. and Regan، نويسنده , , T. and Acharya، نويسنده , , B.S. and Dugad، نويسنده , , S. and Satyanarayana، نويسنده , , B. and Pablo Negret، نويسنده , , J. and Zanabria، نويسنده , , M.، نويسنده ,
Pages :
18
From page :
343
To page :
360
Abstract :
We present the technical design, performance, and stability test results for an LED-based pulser system. The system is used for the Run II Muon Scintillation counters at Fermilabʹs Dط Experiment. Accurate timing information from the scintillation counters is imperative for the proper performance of the muon triggers. The LED Pulser System served in the commissioning of the counters and continues to serve in the monitoring of the performance and the gains of the PMTs. iled description of the system is presented, as well as the results of tests on individual components and integrated system. From the test results, the Dط LED Pulser System tracks the PMT gains with a precision of 0.2%.
Keywords :
Calibration , Monitoring , Pulser , Scintillation , LED
Journal title :
Astroparticle Physics
Record number :
2023145
Link To Document :
بازگشت