• Title of article

    Capacitor-based isolation amplifiers for harsh radiation environments

  • Author/Authors

    Franco، نويسنده , , Francisco J. and Zong، نويسنده , , Yi and de Agapito، نويسنده , , Juan A.، نويسنده ,

  • Pages
    7
  • From page
    367
  • To page
    373
  • Abstract
    Commercial-off-the-shelf (COTS) capacitor-based isolation amplifiers were irradiated at the Portuguese Research Reactor (PRR) in order to determine its tolerance to the displacement damage and total ionising dose (TID). The set of experimental data shows that some of these devices are suitable for zones inside future nuclear facilities where the expected total radiation damage would be below 2.2 × 10 13 1 ‐ MeV neutron / cm 2 and 230 Gy (Si). However, some drawbacks must be taken into account by the electronic designers such as the increase of the output offset voltage and the slight modification of the transmission gain.
  • Keywords
    COTS , Displacement damage , Isolation amplifiers , Total ionising dose (TID)
  • Journal title
    Astroparticle Physics
  • Record number

    2023360