Title of article :
Evaluation of ZnS-family phosphors for neutron detectors using photon counting method
Author/Authors :
Kubota، نويسنده , , N and Katagiri، نويسنده , , M and Kamijo، نويسنده , , K and Nanto، نويسنده , , H، نويسنده ,
Pages :
4
From page :
321
To page :
324
Abstract :
A neutron detection sheet composed of ZnS:Ag as phosphor and 6LiF as neutron converter has been conventionally used for neutron detectors including imaging detectors because of its larger luminescence rate for α ray and shorter lifetime. However, the week point of ZnS:Ag phosphor is the slow component of the lifetime. Thus, we began to investigate other ZnS-family phosphors without the slow component of lifetime for neutron detectors using the photon counting method which needs a smaller number of photons of one order of magnitude. s study, ZnO:Zn, ZnO:Ga, ZnSSe:Ag phosphor ceramics without the slow component of lifetime has been tried to fabricate using an electric furnace or a Spark Plasma Sintering (SPS) apparatus to appropriate for neutron detectors under high counting rates. The ZnO:Zn fabricated by means of the SPS method had the fastest lifetime of 4 ns though its detection efficiency was to be one-eighths as compared with a standard ZnS:Ag/6LiF detection sheet.
Keywords :
Photon counting method , Lifetime , Zinc oxide , ZnS family phosphor , neutron detector
Journal title :
Astroparticle Physics
Record number :
2024194
Link To Document :
بازگشت