Title of article :
Gamma ray transmission imaging detectors using a double gap resistive plate chamber
Author/Authors :
Park، نويسنده , , S. and Ahn، نويسنده , , S.H. and Hong، نويسنده , , B. and Hong، نويسنده , , S.J. and Kang، نويسنده , , T.I. and Kim، نويسنده , , T.J. and Lee، نويسنده , , K.S. and Lim، نويسنده , , J.K. and Moon، نويسنده , , D.H. and Oh، نويسنده , , J.K. and Park، نويسنده , , W.J. and Ryu، نويسنده , , M.S. and Sim، نويسنده , , K.S.، نويسنده ,
Pages :
5
From page :
144
To page :
148
Abstract :
In this paper we report a feasibility study of the gamma ray transmission imaging using a double gap resistive plate chamber. The detector consists of two layers of 2 mm resistive plate chamber (RPC) gaps with two-dimensional read-out strips of 10 mm pitch. Gamma ray transmission images for objects inside a cabinet, using a 10 mCi 137 Cs isotope, were obtained with a pixel resolution of 5 × 5 mm 2 . RPC sensitivities for various gamma ray energies were evaluated by the GEANT-based simulations.
Keywords :
Non-destructive inspection , Multigap RPC , RPC , Compton scattering , Gamma ray scan
Journal title :
Astroparticle Physics
Record number :
2024662