Title of article
A high-voltage test for the ATLAS RPC qualification
Author/Authors
Aielli، نويسنده , , G. and Camarri، نويسنده , , P. and Cardarelli، نويسنده , , R. and Di Ciaccio، نويسنده , , A. and Di Simone، نويسنده , , A. and Liberti، نويسنده , , B. and Santonico، نويسنده , , R.، نويسنده ,
Pages
4
From page
199
To page
202
Abstract
The RPC production sequence for the ATLAS experiment includes a specific test of current absorption at the operating point, which concerns the RPC “gas volumes”, namely the bare detectors not yet assembled with the read-out panels and the mechanical support structures. The test, which is carried out at the production site, consists of two phases. The gas volumes are initially conditioned with pure argon, keeping the voltage constant just above the breakdown value of about 2 kV. The final test, performed after the volumes have undergone inner surface varnishing with linseed oil, is based on the measurement of the current–voltage characteristics with the binary operating gas, C 2 H 2 F 4 / i - C 4 H 10 = 95 / 5 . The results presented here concern 45% of the total foreseen production.
Keywords
Gaseous detectors , RPC , Plastic laminates
Journal title
Astroparticle Physics
Record number
2024673