Title of article :
Timing resolution of the FINUDA scintillation detectors
Author/Authors :
Dalena، نويسنده , , B. and D’Erasmo، نويسنده , , G. and Di Santo، نويسنده , , D. and Fiore، نويسنده , , E.M. and Palomba، نويسنده , , Deirdre M. and Simonetti، نويسنده , , G. and Andronenkov، نويسنده , , A. and Pantaleo، نويسنده , , A. and Paticchio، نويسنده , , V. and Faso، نويسنده , , D.، نويسنده ,
Pages :
11
From page :
276
To page :
286
Abstract :
Experimental characterizations of scintillation detectors timing performance of the internal (TOFINO) and external (TOFONE) scintillator barrels used in FINUDA experiment are presented. asurements take advantage of detecting synchronous particle pairs produced in the reactions, namely e + e - pairs from Bhabha collisions between the primary beams and K + K - pairs from φ (1020) decay. thod used for synchronizing the multiple detectors constituting the scintillator barrels is also described as being carried out in two steps: a rough one online by the injection of laser light pulses flashing the scintillators all together, and a fine one offline exploiting the timing features of e + e - and K + K - pairs.
Keywords :
FINUDA , Scintillation detectors , Timing resolution , TOF