Design and test of a high-speed single-particle beam monitor
Author/Authors :
Pernegger، نويسنده , , H. and Frais-Kِlbl، نويسنده , , H. and Griesmayer، نويسنده , , E. and Kagan، نويسنده , , H.، نويسنده ,
Pages :
7
From page :
108
To page :
114
Abstract :
The paper presents the first test results of a charged-particle solid-state detector with very fast signal response. We used polycrystalline Chemical-Vapor-Deposition (pCVD) diamond as active sensor material and high-bandwidth RF amplifiers to develop a charged-particle detector suitable for high counting rates. The pCVD diamond is segmented with large and small pads for position sensitivity. The detector is intended as a high-speed beam monitor and diagnostics system for proton accelerators in the field of medical ion therapy and high-energy physics experiments.
Keywords :
CVD diamond , Semiconductor radiation detectors , Proton detectors , Proton accelerators , High-speed electronics , Biomedical nuclear imaging
Journal title :
Astroparticle Physics
Record number :
2024993