Title of article :
Performance and applications of a -TPC
Author/Authors :
Miuchi، نويسنده , , Kentaro and Kubo، نويسنده , , Hidetoshi and Nagayoshi، نويسنده , , Tsutomu and Okada، نويسنده , , Yoko and Orito، نويسنده , , Reiko and Takada، نويسنده , , Atsushi and Takeda، نويسنده , , Atsushi and Tanimori، نويسنده , , Toru and Ueno، نويسنده , , Masaru and Bouianov، نويسنده , , Oleg and Bouianov، نويسنده , , Marina، نويسنده ,
Pages :
6
From page :
236
To page :
241
Abstract :
A μ -TPC, a time projection chamber (TPC) which can detect three-dimensional fine tracks of charged particles, was developed and its performance was measured. We developed a μ -TPC with a detection volume of 10 × 10 × 10 cm 3 based on a novel two-dimensional imaging gaseous detector, or the μ -PIC. Fine tracks of charged particles with large energy depositions (protons and electrons) were detected with the μ -TPC. With a pressurized gas, tracks of the minimum ionizing particles were detected. We showed the principle of the application for the time-resolved neutron imaging detector.
Keywords :
Micro-pattern detector , Time-resolved neutron detector , Gaseous detector , Micro-TPC
Journal title :
Astroparticle Physics
Record number :
2025057
Link To Document :
بازگشت