Author/Authors :
Alvarez Pol، نويسنده , , H. and Alves، نويسنده , , R. and Blanco، نويسنده , , A. and Carolino، نويسنده , , N. and Eschke، نويسنده , , J. and Ferreira-Marques، نويسنده , , R. and Fonte، نويسنده , , P. and Garzَn، نويسنده , , J.A. and Gonzلlez Dيaz، نويسنده , , D. and Pereira، نويسنده , , A. and Pietraszko، نويسنده , , J. and Pinhمo، نويسنده , , J. and Policarpo، نويسنده , , A. and Stroth، نويسنده , , J.، نويسنده ,
Abstract :
We present a resistive plate chamber (RPC) prototype for time-of-flight measurements over large areas and at high occupancies, minimizing the inter-channel cross-talk.
edure for the stand-alone calibration of the detector using redundant information is proposed, taking advantage of the very good spatial uniformity observed.
ements were performed at the GSI (Darmstadt) SIS accelerator for primary collisions of C at 1 GeV/u, as a first step towards the projected high acceptance di-electron spectrometer (HADES) upgrade to work at the highest multiplicities expected in Au–Au collisions.
Keywords :
TOF , RPC , Cross-talk , HADES , timing , Ion collisions