Title of article :
Using Constant Slip Ratios to Model Non-Flashing (Frozen) TWo-Phase Flow Through Nozzles
Author/Authors :
Jamerson، Scott C. نويسنده , , Fisher، Harold G. نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
-88
From page :
89
To page :
0
Abstract :
The TPHEM computer program, supplied with the recently published AlChE / CCPS book "Guidelines for Pressure Relief and Effluent Handling Systems", can be used to reproduce a range of two-phase flow data through nozzles. The ability to predict data and design emergency relief systems using simple models is important to the practicing engineer.
Keywords :
ISE , Potentioinctric selectivity , Lipophilic anionci agents , Ternary complex , Lipophilicity , Detection limit
Journal title :
PROCESS SAFETY PROGRESS
Serial Year :
1999
Journal title :
PROCESS SAFETY PROGRESS
Record number :
20254
Link To Document :
بازگشت