• Title of article

    Beam test results of a high-granularity tile/fiber electromagnetic calorimeter

  • Author/Authors

    Ono، نويسنده , , H. and Miyata، نويسنده , , H. and Iba، نويسنده , , S. and Nakajima، نويسنده , , N. and Sanchez، نويسنده , , A.L.C. and Fujii، نويسنده , , Y. and Itoh، نويسنده , , S. and Kajino، نويسنده , , F. and Kanzaki، نويسنده , , J. and Kawagoe، نويسنده , , K. and Kim، نويسنده , , S. and Kishimoto، نويسنده , , S. and Matsumoto، نويسنده , , T. and Matsunaga، نويسنده , , H. and Nagano، نويسنده , , A. and Nakamura، نويسنده , , R. and Takeshi، نويسنده ,

  • Pages
    10
  • From page
    398
  • To page
    407
  • Abstract
    A prototype sampling electromagnetic calorimeter (17.1 radiation lengths) for future linear collider experiments was built, using 4 cm × 4 cm × 1 mm plastic scintillator tiles and 4 mm-thick lead absorber. Wavelength-shifting fibers were used to guide the scintillation light into multi-anode photo-multiplier tubes. The calorimeter was tested at the beam test facility of the High Energy Accelerator Research Organization (KEK) in 2004. In this article we present our beam test results for the tile/fiber calorimeter focusing on the linearity in energy response, the energy resolution, position resolution and uniformity across the tile front face.
  • Keywords
    Calorimeter , Plastic scintillator , Linear collider , Tile
  • Journal title
    Astroparticle Physics
  • Record number

    2025456