Author/Authors :
Yanson، نويسنده , , E.E. and Denisov، نويسنده , , S.P. and Gilitsky، نويسنده , , Yu.V. and Kindin، نويسنده , , V.V. and Kokoulin، نويسنده , , R.P. and Kompaniets، نويسنده , , K.G. and Lipaev، نويسنده , , V.V. and Matyushin، نويسنده , , A.A. and Ovchinnikov، نويسنده , , A.V. and Petrukhin، نويسنده , , A.A. and Prokopenko، نويسنده , , N.N. and Soldatov، نويسنده , , M.M. and Sytin، نويسنده , , A.N.، نويسنده ,
Abstract :
A new type of scintillation detector for shower arrays is considered. The detector represents an octagonal scintillation assembly with total area 1 m2 divided into sectors. Thickness of the plastic is 20 mm. The light is collected by wavelength shifter bars to the photomultiplier, which is located in the center of the detector. A solution to ensure the uniformity of light collection for any coordinate is proposed. Front-end electronics of the detector consists of the controller, the measuring part (QDC, TDC), the system of calibration and the HV converter. The data acquisition system is based on CAN-open standard. There is also a system of temperature stabilization that guarantees not more than 0.5° deviation of the temperature of measuring part elements. Measuring electronics allows obtaining the dynamic range from 1 up to 104 particles and 1 ns time digitization. The time resolution of the detector is about 3 ns.