Author/Authors :
Vartsky، نويسنده , , D. and Mor، نويسنده , , I. J. Goldberg، نويسنده , , M.B. and Mardor، نويسنده , , Anatoly I. and Feldman، نويسنده , , David G. and Bar-Or، نويسنده , , D. and Shor، نويسنده , , A. and Dangendorf، نويسنده , , V. and Laczko، نويسنده , , G. and Breskin، نويسنده , , A. and Chechik، نويسنده , , R.، نويسنده ,
Abstract :
We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Key parameters such as detection efficiency, the amount of energy deposited in the converter and the spatial resolution of both detector variants have been simulated by means of neutron and charged-particle transport codes.
Keywords :
Time-of-flight , MTF , PSF , Radiography , Fast neutron imaging