Title of article
Baseline distortion effect on gamma-ray pulse-height spectra in neutron capture experiments
Author/Authors
Laptev، نويسنده , , A. and Harada، نويسنده , , H. and Nakamura، نويسنده , , S. and Hori، نويسنده , , J. and Igashira، نويسنده , , M. and Ohsaki، نويسنده , , T. and Ohgama، نويسنده , , K.، نويسنده ,
Pages
7
From page
502
To page
508
Abstract
A baseline distortion effect due to gamma-flash at neutron time-of-flight measurement using a pulse neutron source has been investigated. Pulses from C6D6 detectors accumulated by flash-ADC were processed with both standard analog-to-digital converter (ADC) and flash-ADC operational modes. A correction factor of gamma-ray yields, due to baseline shift, was quantitatively obtained by comparing the pulse height spectra of the two data-taking modes. The magnitude of the correction factor depends on the time after gamma-flash and has complex time dependence with a changing sign.
Keywords
Time-of-flight method , C6D6 detector , Detector baseline , Gamma-flash , Flash-ADC , gamma-rays , Neutron capture cross section
Journal title
Astroparticle Physics
Record number
2026460
Link To Document