Author/Authors :
Lasakov، نويسنده , , M.S. and Serebrov، نويسنده , , A.P. and Khusainov، نويسنده , , A.Kh. and Pustovoit، نويسنده , , A. and Borisov، نويسنده , , Yu.V. and Fomin، نويسنده , , A.K. and Geltenbort، نويسنده , , P. and Kon’kov، نويسنده , , O.I. and Kotina، نويسنده , , I.M. and Shablii، نويسنده , , A.I. and Solovei، نويسنده , , V.A. and Vasiliev، نويسنده , , A.V.، نويسنده ,
Abstract :
A silicon UCN detector with an area of 45 cm 2 and with a 6 LiF converter was developed at PNPI. The spectral efficiency of the silicon UCN detector was measured by means of a gravitational spectrometer at ILL. The sandwich-type detector from two silicon plates with a 6 LiF converter placed between them was also studied. Using this type of technology the UCN detector with analysis of polarization was developed and tested. The analyzing power of this detector assembly reaches up to 75% for the main part of UCN spectrum. This UCN detector with analysis of UCN polarization can be used in the new EDM spectrometer.