Author/Authors :
Cano، نويسنده , , Xavier and Graciani، نويسنده , , Ricardo and Gascَn، نويسنده , , José David and Garrido-Lَpez، نويسنده , , Lluيs and Bota، نويسنده , , Sebastià and Herms، نويسنده , , Atilà and Comerma، نويسنده , , Albert and Riera، نويسنده , , Jordi، نويسنده ,
Abstract :
The calorimeter front-end electronics of the LHCb experiment will be located in a region, which is not protected from radiation. Therefore, all the electronics must be qualified to stand some defined radiation levels. The procedure, measurements and results of an irradiation test for every component of the very front-end SPD detector, which is part of the LHCb calorimeter are presented here. All the tested components, except a custom made ASIC, are commercially available.
Keywords :
Triple Voting Register , Single Event Effects , Scintillator Pad Detector SPD , Radiation hardness , Large Hadron Collider LHC