• Title of article

    Detector calibration measurements in CRESST

  • Author/Authors

    Westphal، نويسنده , , W. and Coppi، نويسنده , , C. and Feilitzsch، نويسنده , , F.v. and Isaila، نويسنده , , C. and Jagemann، نويسنده , , T. and Jochum، نويسنده , , J. and Kِnig، نويسنده , , J. and Lachenmaier، نويسنده , , T. and Lanfranchi، نويسنده , , J.-C. and Potzel، نويسنده , , W. and Rau، نويسنده , , W. and Stark، نويسنده , , M. and Wernicke، نويسنده , , D.، نويسنده ,

  • Pages
    3
  • From page
    372
  • To page
    374
  • Abstract
    The CRESST dark matter experiment uses the simultaneous measurement of the scintillation light and the heat signal of a CaWO4 crystal to discriminate between background electron recoil and nuclear recoil events. At the Technical University of Munich calibration measurements have been performed to characterize the detectors. These measurements include the determination of the light output and scintillation time constants of CaWO4 at temperatures below 50 mK. The setup used in these measurements consist of a CaWO4 crystal, which is mounted in a reflective housing together with a silicon light detector carrying an Ir/Au transition edge sensor (TES) evaporated directly onto it.
  • Keywords
    CRESST , Dark matter , Scintillation detectors , Cryogenic detectors
  • Journal title
    Astroparticle Physics
  • Record number

    2028176